Advanced Bionics Harmony Guía para resolver problemas Pagina 1

Busca en linea o descarga Guía para resolver problemas para Equipo de grabación Advanced Bionics Harmony. Advanced Bionics Harmony Troubleshooting guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Troubleshooting Guide

Welcome to the Harmony™ Interactive Troubleshooting GuidePress the button to begin

Pagina 2

Connecting to an FM System1. Ensure that you have the appropriate equipment.• iConnect Earhook• MLxS• Transmitter2. Ensure that the FM system is funct

Pagina 3 - Harmony™ Sound Processor

Connecting to an FM System5. Insert a size 10 zinc air battery into the iConnect6. Turn down the volume on the Harmony Processor7. Turn on the FM tran

Pagina 4

Connecting to an FM System9. Gradually turn up the volume on the Harmony Processor10.Assess performance:• In quiet using an auditory only task• Verify

Pagina 5 - How do I………

I need help troubleshooting the following:• Child is NOT responding to Sound• The Light (LED) on the Processor is Flashing• Sound appears to be Interm

Pagina 6

Child is NOT responding to sound—*Note you have verified no response with a behavioral listening check.1. Verify the Sound Processor is ON• Remember t

Pagina 7

Child is NOT responding to sound—*Note you have verified no response with a behavioral listening check.4. Is the Headpiece positioned over the implant

Pagina 8

Child is NOT responding to sound—*Note you have verified no response with a behavioral listening check.7. Check the Microphone/System Status using the

Pagina 9

Harmony LED Functionality ChartMain MenuBackNext

Pagina 10 - Connecting to an FM System

Child is NOT responding to sound—*Note you have verified no response with a behavioral listening check.10.Remove any materials that may be covering th

Pagina 11

Child is NOT responding to sound—*Note you have verified no response with a behavioral listening check.13.Check for visible damage on the processor14.

Pagina 12

Harmony™ Interactive Troubleshooting GuideThese guides have been created to systematically lead you through active troubleshooting with the Harmony™So

Pagina 13 - • Headpiece will not stay on

The Light (LED) on the Processor is Flashing….1. What is the color of the flashing light?• Orange (Battery)• Green (Microphone)• Red (Communication Er

Pagina 14 - • Make sure they are secure

Orange LED can mean the following:1. PowerCel Status• 3 to 4 quick flashes indicates the PowerCel is fully charged.• 2 quick flashes indicates the Pow

Pagina 15 - Main Menu

Green LED can mean the following…1. Microphone System Status• A green light will flash in response to loud sounds2. Microphone Test Mode• A steady gre

Pagina 16 - Harmony Processor

Red LED can mean the following…1. Lock Status• Blinks at 1 second intervals indicating no lock with the implant2. Intellink™• Rapid blinks indicating

Pagina 17

Sound is intermittent:1. Verify the Sound Processor is ON• Remember that sliding on the PowerCel turns the processor on2. Check your connections inclu

Pagina 18 - • Learn how

4. Is the Headpiece positioned over the implant site?• Busy children can knock it off and may not be able to put it back in place.5. Is your PowerCel

Pagina 19 - • Contact us now!

7. Check the Microphone/System Status using the LED• I would like to learn more about LED functionality 8. Replace the Headpiece/Cable• You should kee

Pagina 20 - • Orange (Battery)

Harmony LED Functionality ChartMain MenuBackNext

Pagina 21 - 3. Change Battery Indicator

10.Remove any materials that may be covering the microphone (i.e. Scarf, Hat, Headband)11.Perform a test of the built in microphone using an empty pro

Pagina 22 - 2. Microphone Test Mode

13.Check for visible damage on the processor14.Contact the audiologist for further troubleshootingBackSound is intermittent—Main Menu

Pagina 23 - 3. Error Conditions

Harmony™ Sound ProcessorWe encourage you to review the processor components before proceeding.Next

Pagina 24 - Sound is intermittent:

Headpiece will not stay on…..1. CAUTION: adding too many magnets to the headpiece may cause physical discomfort and can potentially damage the skin ar

Pagina 25 - Sound is intermittent—

Child’s voice sounds muffled or distorted1. Is the processor turned on?2. Are the connections secure?3. Is the Volume Control in the 12 o’ Clock posit

Pagina 26

Harmony LED Functionality ChartMain MenuBackNext

Pagina 27

Performing a test of the built-in Microphone1. Note: To assess the microphone, you will need to have an empty program slot on the processor. You wil

Pagina 28

Performing a Behavioral Listening Check• Using the Ling Six Sounds (ah, ee, oo, sh, s and mm) you can determine a cochlear implant’s effectiveness by

Pagina 29

Performing a test of the built-in Microphone1. Note: To assess the microphone, you will need to have an empty program slot on the processor. You wil

Pagina 30 - Headpiece will not stay on…

Performing a test of the built-in Microphone1. Note: To assess the microphone, you will need to have an empty program slot on the processor. You wil

Pagina 31 - • Go now

How to Try another Audio Input Source1. By connecting the direct connect system, audio interface cable and either an auxiliary microphone or portable

Pagina 32

How to Try another Audio Input Source1. By connecting the direct connect system, audio interface cable and either an auxiliary microphone or portable

Pagina 33

Cleaning the Processor and PowerCel Contacts1. To prevent intermittent operation of the Processor, contacts on both the PowerCel and Processor should

Pagina 34

Choose from the item below that best Choose from the item below that best describes your situation:describes your situation:I want to learn how to per

Pagina 35

Cleaning the Processor and PowerCel Contacts1. To prevent intermittent operation of the Processor, contacts on both the PowerCel and Processor should

Pagina 36

1. Speak to an Audiologist to ask further questions2. Learn more on-line about the Harmony Processor I need more information……Main Menu

Pagina 37

Speak to an AudiologistPlease call us for further assistance:• Hours of Operation: 5 AM to 5 PM PST(877) 829-0026 US and Canada(800) 678-3575 TTY(661)

Pagina 38

Speak to an AudiologistPlease call us for further assistance:• Hours of Operation: 5 AM to 5 PM PST(877) 829-0026 US and Canada(800) 678-3575 TTY(661)

Pagina 39

Speak to an AudiologistPlease call us for further assistance:• Hours of Operation: 5 AM to 5 PM PST(877) 829-0026 US and Canada(800) 678-3575 TTY(661)

Pagina 40

Speak to an AudiologistPlease call us for further assistance:• Hours of Operation: 5 AM to 5 PM PST(877) 829-0026 US and Canada(800) 678-3575 TTY(661)

Pagina 41 - I need more information……

How do I………• Check the device each day?• Connect to an FM system?BackMain Menu

Pagina 42 - Speak to an Audiologist

How to Verify the Child’s Device is Working1. Is the PowerCel in place and fully charged?• Sliding the PowerCel on the Processor module will turn the

Pagina 43

How to Verify the Child’s Device is Working4. Is the Program Selector in the desired position?• The Harmony can store up to 3 programs (P1, P2, P3).

Pagina 44

How to Verify the Child’s Device is Working7. Is the Headpiece positioned over the Implant (internal device)?• You should feel the magnetic attraction

Pagina 45

Performing a Behavioral Listening Check• Using the Ling Six Sounds (ah, ee, oo, sh, s and mm) you can determine a cochlear implant’s effectiveness by

Comentarios a estos manuales